| STYLE 650 | MINIMUM LOAD FOR 81% ISOLATION (LBS) | ||||||
| LOAD RATING |
MAXIMUM LOAD (LBS) |
FORCING FREQUENCY IN CYCLES PER MINUTE | |||||
| 1500 | 1750 | 2000 | 2500 | 3000 | 3600 | ||
|
B |
600 |
520 |
380 |
300 |
200 |
130 |
100 |
|
C |
800 |
650 |
500 |
320 |
230 |
150 |
|
|
D |
110 |
1100 |
830 |
530 |
380 |
260 |
|
|
E |
1500 |
1400 |
900 |
630 |
430 |
||
Deflections below the line X----X are considered safe practice for static loads; data above that line are useful for calculating deflections under dynamic loads